- GERSTEL
- Agitator/Inkubator
- Automated Liner Exchange (ALEX)
- Automated Tube Exchange (ATEX)
- Centrifugation
- Cooled Injection System (CIS)
- Cryogenic Trapping System CTS
- Disposable Pipette Extraction DPX
- Dynamic Headspace DHS
- Filtration
- Gas sampling system (GSS)
- GRAPHPACK technology
- MAESTRO-software
- Membrane Assisted Solvent Extraction MASE
- Microwave
- MPS Robotic / Robotic Pro
- MPS Workstation, for independent sample preparation.
- mVAP: Multi position evaporation station
- mVORX, Multi Vortex or Orbital Shaker
- Olfactory Detection Port ODP
- On-line SPE for LC: SPExos
- Preparative Fraction Collector PFC
- Pyrolysis for TDU, GERSTEL PYRO
- quickMIX
- Selectable 1D/2D-GC/MS
- Solid Phase Micro Extraction (SPME)
- Solvent Filling Station SFS
- Static Headspace (HS)
- Thermal Desorption System TDS
- TDS-A Autosampler for TDS
- Thermal Desorption Unit TDU
- Thermal Extractor TE
- Tube Conditioner TC
- Tube Standard Preparation System TSPS
- Twister/Stir Bar Sorptive Extraction SBSE
- Ultrasonic bath
- Weighing option
- Agilent
- Leco
- SYFT
- Alpha M.O.S.
- Markes
- The principle of thermal desorption
- Thermal Desorber – Unity xr
- Markes TD autosampler
- Automated canister analysis – CIA Advantage
- In-line air sampling – Air Server 3/8
- 24/7 monitoring with GC analysis – Series 2 TT24-7
- Micro-Chamber/Thermal Extractor
- TD tube conditioner, TC-20
- Sequential sampling of TD tubes – MTS 32
- OI Analytical
- Bruker-IonSense DART
- BioChromato
- Peak Scientific
- IonBench
- VUV Analytics
- References
- Pegasus HT-C
24/7 monitoring with GC analysis – TT24-7
Constant monitoring without “dead” time
The TT 24-7 is a dedicated instrument for true continuous analysis of air without interruption. With this instrument it is possible to achieve near real-time analysis using gas chromatographic analysis.
The system is built upon two parallel cold-trap systems. While one system samples air, the other desorbs and analyse the collected previous sample. Thus, there is continuous and uninterrupted sampling of the surrounding air. Sampling can be done with up to 800mL air/min.
The fast cool down time of the cold trap enables sampling down to 3 min’s intervals, even with 0.25mm columns a complete monitoring cycle is easily achieved in 7 minutes, and with micro-bore columns shorter cycle time may be reached.