- GERSTEL
- Agitator/Inkubator
- Automated Liner Exchange (ALEX)
- Automated Tube Exchange (ATEX)
- Centrifugation
- Cooled Injection System (CIS)
- Cryogenic Trapping System CTS
- Disposable Pipette Extraction DPX
- Dynamic Headspace DHS
- Filtration
- Gas sampling system (GSS)
- GRAPHPACK technology
- MAESTRO-software
- Membrane Assisted Solvent Extraction MASE
- Microwave
- MPS Robotic / Robotic Pro
- MPS Workstation, for independent sample preparation.
- mVAP: Multi position evaporation station
- mVORX, Multi Vortex or Orbital Shaker
- Olfactory Detection Port ODP
- On-line SPE for LC: SPExos
- Preparative Fraction Collector PFC
- Pyrolysis for TDU, GERSTEL PYRO
- quickMIX
- Selectable 1D/2D-GC/MS
- Solid Phase Micro Extraction (SPME)
- Solvent Filling Station SFS
- Static Headspace (HS)
- Thermal Desorption System TDS
- TDS-A Autosampler for TDS
- Thermal Desorption Unit TDU
- Thermal Extractor TE
- Tube Conditioner TC
- Tube Standard Preparation System TSPS
- Twister/Stir Bar Sorptive Extraction SBSE
- Ultrasonic bath
- Weighing option
- Agilent
- Leco
- SYFT
- Alpha M.O.S.
- OI Analytical
- BioChromato
- Peak Scientific
- IonBench
- VUV Analytics
- References
Agilent 5977B, the laboratory workhorse.
Agilent’s single quadrupole is available in three versions, with diffusion or turbo pump. The diffusion pump system has slightly less sensitivity than turbo pump systems, and can only be run with 0.25 columns, but in addition it is a rock solid system.
Turbo-pump systems may accept up to 4mL/min carrier gas, and there is therefore also the possibility to operate with 0.32 columns. If you want the ultimate sensitivity, the turbo pump system also comes with a “High Efficiency source (HES)” ion source.
Our general recommendation is a diffusion pump system if you want a robust system where maximum sensitivity is not required, and you can do with 0.25 columns. If you want a system with optimal sensitivity, chemical ionization and/or running 0.32 columns, a turbo pump system should be selected.
We also like to mention here, that there has been a significant move towards more and more real sensitivity over the past generations of mass detectors:
- Agilent 5973 MS: 60:1 s/n for 1-pg OFN scanning from 50-300 amu at nominal m/z 272 ion.
- Agilent 5975 MS: 600:1 s/n for 1-pg OFN scanning from 50-300 amu at nominal m/z 272 ion.
- Agilent 5977B MS (extractor): 1500:1 s/n for 1-pg OFN scanning from 50-300 amu at nominal m/z 272 ion. IDL (see below): 10fg.
- Agilent 5977B MS (HES source): A new parameter has been introduced by Agilent, the Instrument Detection Limit(IDL). Therefore the Detection Limit is not directly comparable to previous s/n measurements. IDL for 5977B HES is 1.5fg,