- GERSTEL
- Agitator/Inkubator
- Automated Liner Exchange (ALEX)
- Automated Tube Exchange (ATEX)
- Centrifugation
- Cooled Injection System (CIS)
- Cryogenic Trapping System CTS
- Disposable Pipette Extraction DPX
- Dynamic Headspace DHS
- Filtration
- Gas sampling system (GSS)
- GRAPHPACK technology
- MAESTRO-software
- Membrane Assisted Solvent Extraction MASE
- Microwave
- MPS Robotic / Robotic Pro
- MPS Workstation, for independent sample preparation.
- mVAP: Multi position evaporation station
- mVORX, Multi Vortex or Orbital Shaker
- Olfactory Detection Port ODP
- On-line SPE for LC: SPExos
- Preparative Fraction Collector PFC
- Pyrolysis for TDU, GERSTEL PYRO
- quickMIX
- Selectable 1D/2D-GC/MS
- Solid Phase Micro Extraction (SPME)
- Solvent Filling Station SFS
- Static Headspace (HS)
- Thermal Desorption System TDS
- TDS-A Autosampler for TDS
- Thermal Desorption Unit TDU
- Thermal Extractor TE
- Tube Conditioner TC
- Tube Standard Preparation System TSPS
- Twister/Stir Bar Sorptive Extraction SBSE
- Ultrasonic bath
- Weighing option
- Agilent
- Leco
- SYFT
- Alpha M.O.S.
- Markes
- The principle of thermal desorption
- Thermal Desorber – Unity xr
- Markes TD autosampler
- Automated canister analysis – CIA Advantage
- In-line air sampling – Air Server 3/8
- 24/7 monitoring with GC analysis – Series 2 TT24-7
- Micro-Chamber/Thermal Extractor
- TD tube conditioner, TC-20
- Sequential sampling of TD tubes – MTS 32
- OI Analytical
- Bruker-IonSense DART
- BioChromato
- Peak Scientific
- References
Membrane Assisted Solvent Extraction MASE
Water analysis can be complicated if the sample contains a large proportion of suspended substances and foreign particles. Liquid-Liquid extraction is one possibility but is relatively demanding regarding solvent and time.
MASE is a technique where the liquid phases are separated with a semi-permeable membrane and offer solvent extraction with low volumes of solvent.
The solvent addition, and the extraction procedure is done automatically by the MPS.
After addition of the sample, MASE can be performed fully automated by the MPS and embedded into sample preparation procedures. Solvent is added on the “other side” of the membrane. Extracts can be directly injected into GC or GC/MS systems by Large Volume Injection LVI.

Feel free to send us a message via the contact form and we will reply back as soon as possible.
Contact us on order@msconsult.dk
Or call our main number
+45 44 53 93 66
You must be logged in to post a comment.